Electrical Product

  • HAVELLS Distribution Board

    MCB DISTRIBUTION BOARD (SP&N)
    Brand: HAVELL’S

    4 WAY CAPACITY (8″X7″X3″)
    8 WAY CAPACITY (9″X10″X3″)
    12 WAY CAPACITY (9″X13″X3″)
    16 WAY CAPACITY (9″X16″X3″)

    THREE PHASE MCB INCOMING FOR SINGLE PHASE OUTGOING (TPN)

    4 WAY CAPACITY 1+12 (17″X11″X4″)
    6 WAY CAPACITY 1+18 (17.5″X13.5″X4″)
    8 WAY CAPACITY 1+24 (17.5″X16″X4″)
    12 WAY CAPACITY 1+36 (17.5″X21.5″X4″)

    THREE PHASE MCB INCOMING FOR SP/TP MCB OUTGOING (VERTICAL)

    8 WAY CAPACITY (24″X14″X4″)
    12 WAY CAPACITY (26″X14″X4″)

    THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
    A.DOUBLE DOOR TPN VERTICAL & SIZE (G FRAME)

    4 WAY CAPACITY 1+12 (23″X16″X5″)
    8 WAY CAPACITY 1+24 (27″X16″X5″)
    12 WAY CAPACITY 1+36 (31″X16″X5″)

    THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
    A.DOUBLE DOOR TPN VERTICAL & SIZE (A FRAME)

    8 WAY CAPACITY 1+24 (32″X14″X5″)
    12 WAY CAPACITY 1+36 (35″X14″X5″)

    Color: White
    Made in India.
    Warranty: One Year

  • Automatic Changeover Switch (ATS)

    Supports both single-phase and three-phase power systems
    Operating voltage: 220 V (single-phase) and 380 V/230 V (three-phase)
    Frequency: 50 Hz (and compatible with 60 Hz)
    Fabricated from quality materials—European (ABB, Schneider), Korean (Hyundai, LS), Indian (Havells, C&S), or Taiwan (Shihlin) components
    Assembly and testing: Fimext Corporation (Pvt.) Ltd. ensures reliability
    Warranty: 1 year, covering defects in materials or workmanship; voided if tampered without prior approval
    After-sales support: Engineers available within 24 hours; spare parts stocked and ready
    Delivery timeline: Within 5 days of confirmed order and payment

  • Havells Manual Changeover Switch

    Four-pole manual changeover switch conforming to IS/IEC 60947-3 standards
    Frame ratings available from 40 A up to 3150 A
    Offers open execution and stainless-steel enclosure options
    Incorporates phase separators and handle with door-interlock kit as integral features
    Optional auxiliary contacts available for signaling or electrical interlocking
    Designed for quick-make, quick-break switching with high durability and vibration resistance
    IP ratings: IP2X standard; IP32 (SS enclosure), IP43 available on request
    Ambient operating conditions: up to +50 °C, 80 % humidity at 55 °C or 95 % at 40 °C, altitude up to 2000 m without derating
    Compact size, extended outgoing terminals, and mounting flexibility (360° orientation)

  • HYUNDAI Miniature Circuit Breaker (MCB)

    Protection Type: Overload and short-circuit protection (HiBD type)
    Rated Voltage: AC 240 V / AC 415 V
    Rated Current Range: 1 mAh to 125 mAh
    Breaking Capacity: 6 kA or 10 kA (depending on series)
    Number of Poles: 1P, 2P, 3P, 4P (including 1+N, 3+N variants)
    Tripping Curve Types: B, C, D curves for customizing trip characteristics
    Mounting: 35 mm DIN-rail mountable structure; uniform terminal positions
    Padlockable in ON/OFF positions
    Test button for earth-leakage series (RCCB types)
    Untouchable terminals, IP20 compliance
    Design: Flame-retardant molded plastic casing; unified appearance across series
    Standards & Certification: IEC/EN compliance, certified by KEMA, GOST-R, TSE, BV, CE
    Operating temperature: –5 °C to +55 °C
    Terminal capacity up to 35 mm²
    Torque rating: ~2 N·m

  • HYUNDAI Molded Case Circuit Breaker (MCCB)

    Current rating range: 15 A to 1600 A
    Short-circuit breaking capacity: 5 kA to 150 kA
    Rated insulation voltage (Ui): 1000 V
    Service breaking capacity (Ics): 100% of Icu
    Thermal-magnetic (Hi Series) rated current: 3 A to 800 A
    Thermal-magnetic breaking capacity (Hi Series): 5 kA to 130 kA at 415 V
    Electronic-type rated current: 20 A to 1200 A
    Electronic-type breaking capacity: 50 kA to 130 kA at 415 V
    Compact and lightweight design: depth ~60 mm, panel cutout, space-saving
    Advanced “cassette” modular design for easy installation, maintenance, and customization
    Standard trip mechanisms: thermal, magnetic, adjustable, hydraulic-magnetic; multiple trip time settings (LTD, STD, INST, PTA, GFT, Pre-trip alarm)
    Operating environment: ambient temperature from –25 °C to +50 °C, humidity 45–85%, altitude up to 2000 m, IP20 protection

  • HYUNDAI Residual Current Circuit Breaker (RCCB)

    Rated operating voltage: AC 240 V / 415 V
    Number of poles: 2 (1+N) and 4 (3+N) option
    Rated current (In): 16, 25, 32, 40, 63 A (HRC63 series); HRC100 / HiRC100 (63, 80, 100 A)
    Rated residual operating current: 10, 30, 100, 300, 500 mA
    Rated conditional short-circuit current capacity: HRC63 (10 kA); HiRC63 (6 k); HiRC100 (10 kA)
    Type: supports AC (and Type A in some variants) trip characteristics
    Current limiting structure for added protection
    High resistance to fire, temperature, and mechanical damage
    Clear ON/OFF indicators plus leakage fault indication windows
    Dual terminal connections for cable and busbar flexibility
    Test button for regular inspection of protective function

Call Us Now
WhatsApp
Need Help?

Main Menu

Call us