Electrical Product

  • HYUNDAI Residual Current Circuit Breaker (RCCB)

    Rated operating voltage: AC 240 V / 415 V
    Number of poles: 2 (1+N) and 4 (3+N) option
    Rated current (In): 16, 25, 32, 40, 63 A (HRC63 series); HRC100 / HiRC100 (63, 80, 100 A)
    Rated residual operating current: 10, 30, 100, 300, 500 mA
    Rated conditional short-circuit current capacity: HRC63 (10 kA); HiRC63 (6 k); HiRC100 (10 kA)
    Type: supports AC (and Type A in some variants) trip characteristics
    Current limiting structure for added protection
    High resistance to fire, temperature, and mechanical damage
    Clear ON/OFF indicators plus leakage fault indication windows
    Dual terminal connections for cable and busbar flexibility
    Test button for regular inspection of protective function

  • HYUNDAI Molded Case Circuit Breaker (MCCB)

    Current rating range: 15 A to 1600 A
    Short-circuit breaking capacity: 5 kA to 150 kA
    Rated insulation voltage (Ui): 1000 V
    Service breaking capacity (Ics): 100% of Icu
    Thermal-magnetic (Hi Series) rated current: 3 A to 800 A
    Thermal-magnetic breaking capacity (Hi Series): 5 kA to 130 kA at 415 V
    Electronic-type rated current: 20 A to 1200 A
    Electronic-type breaking capacity: 50 kA to 130 kA at 415 V
    Compact and lightweight design: depth ~60 mm, panel cutout, space-saving
    Advanced “cassette” modular design for easy installation, maintenance, and customization
    Standard trip mechanisms: thermal, magnetic, adjustable, hydraulic-magnetic; multiple trip time settings (LTD, STD, INST, PTA, GFT, Pre-trip alarm)
    Operating environment: ambient temperature from –25 °C to +50 °C, humidity 45–85%, altitude up to 2000 m, IP20 protection

  • HYUNDAI Miniature Circuit Breaker (MCB)

    Protection Type: Overload and short-circuit protection (HiBD type)
    Rated Voltage: AC 240 V / AC 415 V
    Rated Current Range: 1 mAh to 125 mAh
    Breaking Capacity: 6 kA or 10 kA (depending on series)
    Number of Poles: 1P, 2P, 3P, 4P (including 1+N, 3+N variants)
    Tripping Curve Types: B, C, D curves for customizing trip characteristics
    Mounting: 35 mm DIN-rail mountable structure; uniform terminal positions
    Padlockable in ON/OFF positions
    Test button for earth-leakage series (RCCB types)
    Untouchable terminals, IP20 compliance
    Design: Flame-retardant molded plastic casing; unified appearance across series
    Standards & Certification: IEC/EN compliance, certified by KEMA, GOST-R, TSE, BV, CE
    Operating temperature: –5 °C to +55 °C
    Terminal capacity up to 35 mm²
    Torque rating: ~2 N·m

  • Manual Changeover Switch

    Four-pole manual changeover switch conforming to IS/IEC 60947-3 standards
    Frame ratings available from 40 A up to 3150 A
    Offers open execution and stainless-steel enclosure options
    Incorporates phase separators and handle with door-interlock kit as integral features
    Optional auxiliary contacts available for signaling or electrical interlocking
    Designed for quick-make, quick-break switching with high durability and vibration resistance
    IP ratings: IP2X standard; IP32 (SS enclosure), IP43 available on request
    Ambient operating conditions: up to +50 °C, 80 % humidity at 55 °C or 95 % at 40 °C, altitude up to 2000 m without derating
    Compact size, extended outgoing terminals, and mounting flexibility (360° orientation)

  • Automatic Changeover Switch

    Supports both single-phase and three-phase power systems
    Operating voltage: 220 V (single-phase) and 380 V/230 V (three-phase)
    Frequency: 50 Hz (and compatible with 60 Hz)
    Fabricated from quality materials—European (ABB, Schneider), Korean (Hyundai, LS), Indian (Havells, C&S), or Taiwan (Shihlin) components
    Assembly and testing: Fimext Corporation (Pvt.) Ltd. ensures reliability
    Warranty: 1 year, covering defects in materials or workmanship; voided if tampered without prior approval
    After-sales support: Engineers available within 24 hours; spare parts stocked and ready
    Delivery timeline: Within 5 days of confirmed order and payment

  • HAVELLS Distribution Board (DB Board)

    MCB DISTRIBUTION BOARD (SP&N)
    Brand: HAVELL’S

    4 WAY CAPACITY (8″X7″X3″)
    8 WAY CAPACITY (9″X10″X3″)
    12 WAY CAPACITY (9″X13″X3″)
    16 WAY CAPACITY (9″X16″X3″)

    THREE PHASE MCB INCOMING FOR SINGLE PHASE OUTGOING (TPN)

    4 WAY CAPACITY 1+12 (17″X11″X4″)
    6 WAY CAPACITY 1+18 (17.5″X13.5″X4″)
    8 WAY CAPACITY 1+24 (17.5″X16″X4″)
    12 WAY CAPACITY 1+36 (17.5″X21.5″X4″)

    THREE PHASE MCB INCOMING FOR SP/TP MCB OUTGOING (VERTICAL)

    8 WAY CAPACITY (24″X14″X4″)
    12 WAY CAPACITY (26″X14″X4″)

    THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
    A.DOUBLE DOOR TPN VERTICAL & SIZE (G FRAME)

    4 WAY CAPACITY 1+12 (23″X16″X5″)
    8 WAY CAPACITY 1+24 (27″X16″X5″)
    12 WAY CAPACITY 1+36 (31″X16″X5″)

    THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
    A.DOUBLE DOOR TPN VERTICAL & SIZE (A FRAME)

    8 WAY CAPACITY 1+24 (32″X14″X5″)
    12 WAY CAPACITY 1+36 (35″X14″X5″)

    Color: White
    Made in India.
    Warranty: One Year

Need Help?