Electrical Product
Best Seller Items
-
HYUNDAI Residual Current Circuit Breaker (RCCB)
Rated operating voltage: AC 240 V / 415 V
Number of poles: 2 (1+N) and 4 (3+N) option
Rated current (In): 16, 25, 32, 40, 63 A (HRC63 series); HRC100 / HiRC100 (63, 80, 100 A)
Rated residual operating current: 10, 30, 100, 300, 500 mA
Rated conditional short-circuit current capacity: HRC63 (10 kA); HiRC63 (6 k); HiRC100 (10 kA)
Type: supports AC (and Type A in some variants) trip characteristics
Current limiting structure for added protection
High resistance to fire, temperature, and mechanical damage
Clear ON/OFF indicators plus leakage fault indication windows
Dual terminal connections for cable and busbar flexibility
Test button for regular inspection of protective function
-
HAVELLS Distribution Board (DB Board)
MCB DISTRIBUTION BOARD (SP&N)
Brand: HAVELL’S4 WAY CAPACITY (8″X7″X3″)
8 WAY CAPACITY (9″X10″X3″)
12 WAY CAPACITY (9″X13″X3″)
16 WAY CAPACITY (9″X16″X3″)
THREE PHASE MCB INCOMING FOR SINGLE PHASE OUTGOING (TPN)
4 WAY CAPACITY 1+12 (17″X11″X4″)
6 WAY CAPACITY 1+18 (17.5″X13.5″X4″)
8 WAY CAPACITY 1+24 (17.5″X16″X4″)
12 WAY CAPACITY 1+36 (17.5″X21.5″X4″)
THREE PHASE MCB INCOMING FOR SP/TP MCB OUTGOING (VERTICAL)
8 WAY CAPACITY (24″X14″X4″)
12 WAY CAPACITY (26″X14″X4″)
THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
A.DOUBLE DOOR TPN VERTICAL & SIZE (G FRAME)4 WAY CAPACITY 1+12 (23″X16″X5″)
8 WAY CAPACITY 1+24 (27″X16″X5″)
12 WAY CAPACITY 1+36 (31″X16″X5″)
THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
A.DOUBLE DOOR TPN VERTICAL & SIZE (A FRAME)8 WAY CAPACITY 1+24 (32″X14″X5″)
12 WAY CAPACITY 1+36 (35″X14″X5″)
Color: White
Made in India.
Warranty: One Year -
Automatic Changeover Switch
Supports both single-phase and three-phase power systems
Operating voltage: 220 V (single-phase) and 380 V/230 V (three-phase)
Frequency: 50 Hz (and compatible with 60 Hz)
Fabricated from quality materials—European (ABB, Schneider), Korean (Hyundai, LS), Indian (Havells, C&S), or Taiwan (Shihlin) components
Assembly and testing: Fimext Corporation (Pvt.) Ltd. ensures reliability
Warranty: 1 year, covering defects in materials or workmanship; voided if tampered without prior approval
After-sales support: Engineers available within 24 hours; spare parts stocked and ready
Delivery timeline: Within 5 days of confirmed order and payment
-
Manual Changeover Switch
Four-pole manual changeover switch conforming to IS/IEC 60947-3 standards
Frame ratings available from 40 A up to 3150 A
Offers open execution and stainless-steel enclosure options
Incorporates phase separators and handle with door-interlock kit as integral features
Optional auxiliary contacts available for signaling or electrical interlocking
Designed for quick-make, quick-break switching with high durability and vibration resistance
IP ratings: IP2X standard; IP32 (SS enclosure), IP43 available on request
Ambient operating conditions: up to +50 °C, 80 % humidity at 55 °C or 95 % at 40 °C, altitude up to 2000 m without derating
Compact size, extended outgoing terminals, and mounting flexibility (360° orientation)
-
HYUNDAI Miniature Circuit Breaker (MCB)
Protection Type: Overload and short-circuit protection (HiBD type)
Rated Voltage: AC 240 V / AC 415 V
Rated Current Range: 1 mAh to 125 mAh
Breaking Capacity: 6 kA or 10 kA (depending on series)
Number of Poles: 1P, 2P, 3P, 4P (including 1+N, 3+N variants)
Tripping Curve Types: B, C, D curves for customizing trip characteristics
Mounting: 35 mm DIN-rail mountable structure; uniform terminal positions
Padlockable in ON/OFF positions
Test button for earth-leakage series (RCCB types)
Untouchable terminals, IP20 compliance
Design: Flame-retardant molded plastic casing; unified appearance across series
Standards & Certification: IEC/EN compliance, certified by KEMA, GOST-R, TSE, BV, CE
Operating temperature: –5 °C to +55 °C
Terminal capacity up to 35 mm²
Torque rating: ~2 N·m
-
HYUNDAI Molded Case Circuit Breaker (MCCB)
Current rating range: 15 A to 1600 A
Short-circuit breaking capacity: 5 kA to 150 kA
Rated insulation voltage (Ui): 1000 V
Service breaking capacity (Ics): 100% of Icu
Thermal-magnetic (Hi Series) rated current: 3 A to 800 A
Thermal-magnetic breaking capacity (Hi Series): 5 kA to 130 kA at 415 V
Electronic-type rated current: 20 A to 1200 A
Electronic-type breaking capacity: 50 kA to 130 kA at 415 V
Compact and lightweight design: depth ~60 mm, panel cutout, space-saving
Advanced “cassette” modular design for easy installation, maintenance, and customization
Standard trip mechanisms: thermal, magnetic, adjustable, hydraulic-magnetic; multiple trip time settings (LTD, STD, INST, PTA, GFT, Pre-trip alarm)
Operating environment: ambient temperature from –25 °C to +50 °C, humidity 45–85%, altitude up to 2000 m, IP20 protection
-
HYUNDAI Residual Current Circuit Breaker (RCCB)
Rated operating voltage: AC 240 V / 415 V
Number of poles: 2 (1+N) and 4 (3+N) option
Rated current (In): 16, 25, 32, 40, 63 A (HRC63 series); HRC100 / HiRC100 (63, 80, 100 A)
Rated residual operating current: 10, 30, 100, 300, 500 mA
Rated conditional short-circuit current capacity: HRC63 (10 kA); HiRC63 (6 k); HiRC100 (10 kA)
Type: supports AC (and Type A in some variants) trip characteristics
Current limiting structure for added protection
High resistance to fire, temperature, and mechanical damage
Clear ON/OFF indicators plus leakage fault indication windows
Dual terminal connections for cable and busbar flexibility
Test button for regular inspection of protective function
-
HYUNDAI Molded Case Circuit Breaker (MCCB)
Current rating range: 15 A to 1600 A
Short-circuit breaking capacity: 5 kA to 150 kA
Rated insulation voltage (Ui): 1000 V
Service breaking capacity (Ics): 100% of Icu
Thermal-magnetic (Hi Series) rated current: 3 A to 800 A
Thermal-magnetic breaking capacity (Hi Series): 5 kA to 130 kA at 415 V
Electronic-type rated current: 20 A to 1200 A
Electronic-type breaking capacity: 50 kA to 130 kA at 415 V
Compact and lightweight design: depth ~60 mm, panel cutout, space-saving
Advanced “cassette” modular design for easy installation, maintenance, and customization
Standard trip mechanisms: thermal, magnetic, adjustable, hydraulic-magnetic; multiple trip time settings (LTD, STD, INST, PTA, GFT, Pre-trip alarm)
Operating environment: ambient temperature from –25 °C to +50 °C, humidity 45–85%, altitude up to 2000 m, IP20 protection
-
HYUNDAI Miniature Circuit Breaker (MCB)
Protection Type: Overload and short-circuit protection (HiBD type)
Rated Voltage: AC 240 V / AC 415 V
Rated Current Range: 1 mAh to 125 mAh
Breaking Capacity: 6 kA or 10 kA (depending on series)
Number of Poles: 1P, 2P, 3P, 4P (including 1+N, 3+N variants)
Tripping Curve Types: B, C, D curves for customizing trip characteristics
Mounting: 35 mm DIN-rail mountable structure; uniform terminal positions
Padlockable in ON/OFF positions
Test button for earth-leakage series (RCCB types)
Untouchable terminals, IP20 compliance
Design: Flame-retardant molded plastic casing; unified appearance across series
Standards & Certification: IEC/EN compliance, certified by KEMA, GOST-R, TSE, BV, CE
Operating temperature: –5 °C to +55 °C
Terminal capacity up to 35 mm²
Torque rating: ~2 N·m
-
Manual Changeover Switch
Four-pole manual changeover switch conforming to IS/IEC 60947-3 standards
Frame ratings available from 40 A up to 3150 A
Offers open execution and stainless-steel enclosure options
Incorporates phase separators and handle with door-interlock kit as integral features
Optional auxiliary contacts available for signaling or electrical interlocking
Designed for quick-make, quick-break switching with high durability and vibration resistance
IP ratings: IP2X standard; IP32 (SS enclosure), IP43 available on request
Ambient operating conditions: up to +50 °C, 80 % humidity at 55 °C or 95 % at 40 °C, altitude up to 2000 m without derating
Compact size, extended outgoing terminals, and mounting flexibility (360° orientation)
-
Automatic Changeover Switch
Supports both single-phase and three-phase power systems
Operating voltage: 220 V (single-phase) and 380 V/230 V (three-phase)
Frequency: 50 Hz (and compatible with 60 Hz)
Fabricated from quality materials—European (ABB, Schneider), Korean (Hyundai, LS), Indian (Havells, C&S), or Taiwan (Shihlin) components
Assembly and testing: Fimext Corporation (Pvt.) Ltd. ensures reliability
Warranty: 1 year, covering defects in materials or workmanship; voided if tampered without prior approval
After-sales support: Engineers available within 24 hours; spare parts stocked and ready
Delivery timeline: Within 5 days of confirmed order and payment
-
HAVELLS Distribution Board (DB Board)
MCB DISTRIBUTION BOARD (SP&N)
Brand: HAVELL’S4 WAY CAPACITY (8″X7″X3″)
8 WAY CAPACITY (9″X10″X3″)
12 WAY CAPACITY (9″X13″X3″)
16 WAY CAPACITY (9″X16″X3″)
THREE PHASE MCB INCOMING FOR SINGLE PHASE OUTGOING (TPN)
4 WAY CAPACITY 1+12 (17″X11″X4″)
6 WAY CAPACITY 1+18 (17.5″X13.5″X4″)
8 WAY CAPACITY 1+24 (17.5″X16″X4″)
12 WAY CAPACITY 1+36 (17.5″X21.5″X4″)
THREE PHASE MCB INCOMING FOR SP/TP MCB OUTGOING (VERTICAL)
8 WAY CAPACITY (24″X14″X4″)
12 WAY CAPACITY (26″X14″X4″)
THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
A.DOUBLE DOOR TPN VERTICAL & SIZE (G FRAME)4 WAY CAPACITY 1+12 (23″X16″X5″)
8 WAY CAPACITY 1+24 (27″X16″X5″)
12 WAY CAPACITY 1+36 (31″X16″X5″)
THREE PHASE MCCB INCOMING OUTGOING MCB (LOAD LINE)
A.DOUBLE DOOR TPN VERTICAL & SIZE (A FRAME)8 WAY CAPACITY 1+24 (32″X14″X5″)
12 WAY CAPACITY 1+36 (35″X14″X5″)
Color: White
Made in India.