• HYUNDAI Residual Current Circuit Breaker (RCCB)

    Rated operating voltage: AC 240 V / 415 V
    Number of poles: 2 (1+N) and 4 (3+N) option
    Rated current (In): 16, 25, 32, 40, 63 A (HRC63 series); HRC100 / HiRC100 (63, 80, 100 A)
    Rated residual operating current: 10, 30, 100, 300, 500 mA
    Rated conditional short-circuit current capacity: HRC63 (10 kA); HiRC63 (6 k); HiRC100 (10 kA)
    Type: supports AC (and Type A in some variants) trip characteristics
    Current limiting structure for added protection
    High resistance to fire, temperature, and mechanical damage
    Clear ON/OFF indicators plus leakage fault indication windows
    Dual terminal connections for cable and busbar flexibility
    Test button for regular inspection of protective function

  • HYUNDAI Molded Case Circuit Breaker (MCCB)

    Current rating range: 15 A to 1600 A
    Short-circuit breaking capacity: 5 kA to 150 kA
    Rated insulation voltage (Ui): 1000 V
    Service breaking capacity (Ics): 100% of Icu
    Thermal-magnetic (Hi Series) rated current: 3 A to 800 A
    Thermal-magnetic breaking capacity (Hi Series): 5 kA to 130 kA at 415 V
    Electronic-type rated current: 20 A to 1200 A
    Electronic-type breaking capacity: 50 kA to 130 kA at 415 V
    Compact and lightweight design: depth ~60 mm, panel cutout, space-saving
    Advanced “cassette” modular design for easy installation, maintenance, and customization
    Standard trip mechanisms: thermal, magnetic, adjustable, hydraulic-magnetic; multiple trip time settings (LTD, STD, INST, PTA, GFT, Pre-trip alarm)
    Operating environment: ambient temperature from –25 °C to +50 °C, humidity 45–85%, altitude up to 2000 m, IP20 protection

  • HYUNDAI Miniature Circuit Breaker (MCB)

    Protection Type: Overload and short-circuit protection (HiBD type)
    Rated Voltage: AC 240 V / AC 415 V
    Rated Current Range: 1 mAh to 125 mAh
    Breaking Capacity: 6 kA or 10 kA (depending on series)
    Number of Poles: 1P, 2P, 3P, 4P (including 1+N, 3+N variants)
    Tripping Curve Types: B, C, D curves for customizing trip characteristics
    Mounting: 35 mm DIN-rail mountable structure; uniform terminal positions
    Padlockable in ON/OFF positions
    Test button for earth-leakage series (RCCB types)
    Untouchable terminals, IP20 compliance
    Design: Flame-retardant molded plastic casing; unified appearance across series
    Standards & Certification: IEC/EN compliance, certified by KEMA, GOST-R, TSE, BV, CE
    Operating temperature: –5 °C to +55 °C
    Terminal capacity up to 35 mm²
    Torque rating: ~2 N·m

Need Help?

Main Menu

Call us